Measures: Range of motion of a specific joint (degrees, passive or active)
Table of Contents
Difficulty: Moderate | Category: Flexibility
Protocol
Goniometric assessment is the most widely used clinical method for measuring the passive and/or active range of motion (ROM) of any joint in degrees. The goniometer consists of three parts: a stationary arm, a movable arm, and a central axis point. Reference points are placed on the anatomical landmarks of the relevant joint. General protocol: The participant is positioned appropriately on the table. The joint is brought to the specified anatomical position. The goniometer’s fixed arm is aligned along the long axis of the proximal segment, and the movable arm along the long axis of the distal segment. The central axis is positioned at the anatomical joint center. For passive ROM, the test administrator moves the joint; for active ROM, the participant performs the movement with their own muscles. When the range limit is reached, the angle is read and recorded. According to the SFTR method (Sagittal/Frontal/Transverse/Rotation), start and end values are recorded. The most commonly measured joints are: shoulder (flexion/extension/abduction/internal-external rotation), elbow (flexion/supination/pronation), hip (flexion/abduction/rotation), knee (flexion/extension), and ankle (dorsiflexion/plantar flexion/inversion/eversion). For reliability, the average of two measurements is taken and right-left comparison is performed. Some AAOS reference values: hip flexion 120°, shoulder abduction 180°, knee flexion 135°, ankle dorsiflexion 20° and plantar flexion 50°.
Formula
ROM angle (°), reported in SFTR neutral-zero format
Equipment Required
standard goniometer (360° or 180°), examination table, recording form
Interpretation
There is no single widely accepted normative table for this test. Results are best interpreted against the person’s previous measurements with the same protocol and equipment (and, where relevant, left-right comparison).
Practical Applications
Standard method for clinical evaluation, rehabilitation monitoring, and documentation for formal disability assessments.
Limitations
Measurement errors can arise from incorrect axis positioning; intrarater reliability is high, interrater reliability is moderate.
Related Tests: Dorsiflexion Range of Motion Test, Thomas Test (Hip Flexor Flexibility), Straight Leg Raise Test (SLR)
Sources: Norkin CC & White DJ, 2009, Measurement of Joint Motion, 4th Ed; American Academy of Orthopaedic Surgeons, 1965, Joint Motion Manual
Hüseyin Akbulut is the founder of Sporeus and author of THRESHOLD (EŞİK), a 540-page Turkish-language book on endurance science.
- 540pp THRESHOLD Book
- MSc Sport Sciences
- Marmara University
Protocol Goniometric assessment is the most widely used clinical method for measuring the passive and/or active range of motion (ROM) of any joint in degrees. The goniometer consists of three parts: a stationary arm, a movable arm, and a central axis point. Reference points are placed on the anatomical landmarks of the relevant joint. General protocol: The participant is positioned appropriately on the table. The joint is brought to the specified anatomical position. The goniometer's fixed arm is aligned along the long axis of the proximal segment, and the movable arm along the long axis of the distal segment. The central axis is positioned at the anatomical joint center. For passive ROM, the test administrator moves the joint; for active ROM, the participant performs the movement with their own muscles. When the range limit is reached, the angle is read and recorded. According to the SFTR method (Sagittal/Frontal/Transverse/Rotation), start and end values are recorded. The most commonly measured joints are: shoulder (flexion/extension/abduction/internal-external rotation), elbow (flexion/supination/pronation), hip (flexion/abduction/rotation), knee (flexion/extension), and ankle (dorsiflexion/plantar flexion/inversion/eversion). For reliability, the average of two measurements is taken and right-left comparison is performed. Some AAOS reference values: hip flexion 120°, shoulder abduction 180°, knee flexion 135°, ankle dorsiflexion 20° and plantar flexion 50°. Formula
ROM angle (°), reported in SFTR neutral-zero format
Equipment Required
standard goniometer (360° or 180°), examination table, recording form
Interpretation
There is no single widely accepted normative table for this test. Results are best interpreted against the person's previous measurements with the same protocol and equipment (and, where relevant, left-right comparison).