Hüseyin Akbulut, MSc (2026). Active Knee Extension Test: Protocol and Application. Sporeus. Retrieved, November 24, 2026. https://sporeus.com/en/egzersiz-testleri-en/active-knee-extension-test/
Measures: Hamstring flexibility (knee extension deficit with the hip at 90°, degrees)
Table of Contents
Difficulty: Easy | Category: Flexibility
Protocol
The Active Knee Extension Test is a clinical protocol for measuring hamstring muscle flexibility in a more isolated and reliable manner compared to the standard SLR test. The participant lies supine; the hip is maintained at 90° flexion while the knee is also initially at 90° flexion. The participant must keep the opposite leg flat on the table. While the test administrator stabilizes the hip at 90°, the participant is asked to straighten the knee as much as possible. If the knee cannot reach full extension, the angle at maximum reach is measured with a goniometer. The value is reported as the difference from 0° (degree of deficit): some sources regard a deficit of up to 20° as normal, but values vary widely even in healthy people; clearly larger deficits and left-right differences suggest hamstring tightness. The test is applied for both legs. This test has less neural tension component compared to SLR; therefore it is considered more suitable for assessing muscle shortness. It is used as a regular follow-up measurement in runners, football players, and athletes who have experienced hamstring strain. In the rehabilitation process, measurements repeated at short intervals provide valuable data for tracking flexibility gains.
Formula
Knee extension deficit (°) = knee flexion angle remaining short of full extension (0°) with the hip held at 90°
Equipment Required
examination table, goniometer
Interpretation
There is no single widely accepted normative table for this test. Results are best interpreted against the person’s previous measurements with the same protocol and equipment (and, where relevant, left-right comparison).
Practical Applications
Distinguishes hamstring shortness from neural tension; reliable for rehabilitation monitoring.
Limitations
Stabilizing the hip at 90° requires standardization; active contraction capacity affects results.
Related Tests: Straight Leg Raise Test (SLR), Thomas Test (Hip Flexor Flexibility), Sit-and-Reach Test
Sources: Gajdosik RL & Lusin G, 1983, Physical Therapy
Hüseyin Akbulut is the founder of Sporeus and author of THRESHOLD (EŞİK), a 540-page Turkish-language book on endurance science.
- 540pp THRESHOLD Book
- MSc Sport Sciences
- Marmara University
Protocol The Active Knee Extension Test is a clinical protocol for measuring hamstring muscle flexibility in a more isolated and reliable manner compared to the standard SLR test. The participant lies supine; the hip is maintained at 90° flexion while the knee is also initially at 90° flexion. The participant must keep the opposite leg flat on the table. While the test administrator stabilizes the hip at 90°, the participant is asked to straighten the knee as much as possible. If the knee cannot reach full extension, the angle at maximum reach is measured with a goniometer. The value is reported as the difference from 0° (degree of deficit): some sources regard a deficit of up to 20° as normal, but values vary widely even in healthy people; clearly larger deficits and left-right differences suggest hamstring tightness. The test is applied for both legs. This test has less neural tension component compared to SLR; therefore it is considered more suitable for assessing muscle shortness. It is used as a regular follow-up measurement in runners, football players, and athletes who have experienced hamstring strain. In the rehabilitation process, measurements repeated at short intervals provide valuable data for tracking flexibility gains. Formula
Knee extension deficit (°) = knee flexion angle remaining short of full extension (0°) with the hip held at 90°
Equipment Required
examination table, goniometer
Interpretation
There is no single widely accepted normative table for this test. Results are best interpreted against the person's previous measurements with the same protocol and equipment (and, where relevant, left-right comparison).